Products > A2F100 Cable Gland
explosive atmosphere single sela internationally approved gland

A2F100 Cable Gland
explosive atmosphere single sela internationally approved gland

Internationally Approved, Explosive Atmosphere Cable Gland

• Complies 100% with IEC 60079-0 cable retention requirements
• No external cable clamping required
• No special conditions for safe use
• Displacement type flameproof seal
• Deluge protected
• -60°C to +130°C
• Internationlly marked, IECEx, ATEX

For all types of Unarmoured & Braided Cables

Description

Technical

Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications* Impact = Level 8, Retention = Class B
Enclosure Protection IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
ATEX Certificate SIRA16ATEX1018, SIRA16ATEX4020
Code of Protection II 2G, II 1D Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da
II 3G Ex nRc IIC Gc, I M2 Ex db I Mb, Ex eb I Mb
Compliance Standards EN 60079-0,1,7,15,31
IECEx Certificate IECEx SIR 16.0006
Code of Protection Ex db IIC Gb, Ex eb IIC Gb, Ex nRc IIC Gc, Ex ta IIIC Da, Ex db I Mb, Ex eb I Mb
Compliance Standards IEC 60079-0,1,7,15,31
RETIE Certificate 03866
Marine Approvals LRS: 01/00172, DNV: E-13848, ABS: 14-LD234401A-4-PDA
Ingress Protection Rating ** IP66, IP67 & IP68**
Deluge Protection Compliance DTS01 : 91
Cable Gland Material Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium
Seal Material CMP SOLO LSF Halogen Free Thermoset Elastomer
Cable Type Unarmoured & Braided
Sealing Technique CMP Unique Displacement Seal Concept
Sealing Area(s) Cable Outer Sheath
Optional Accessories Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
Optional Installation Tools Spanners

Product Table

Metric

Cable Gland Size Available Entry Threads “C”
(Alternate Metric Thread Lengths Available)
Overall Cable Diameter “A” Across Flats “D” Across Corners “D” Protrusion Length “F” Combined Ordering Reference
(*Brass Metric)
Shroud Cable
Gland Weight
(Kgs)
Standard Option
Metric Thread Length (Metric) “E” NPT Thread Length (NPT) “E” NPT Min Max Max Max Size Type Ordering Suffix
16 M16 15.0 3.2 8.0 24.0 26.4 34.9 16 A2F100 1RA PVC04 0.07
20S16 M20 15.0 ½” 19.9 ¾” 3.2 8.0 24.0 26.4 30.4 20S16 A2F100 1RA PVC04 0.08
20S M20 15.0 ½” 19.9 ¾” 6.5 11.2 24.0 26.4 31.9 20S A2F100 1RA PVC04 0.07
20 M20 15.0 ½” 19.9 ¾” 7.0 13.5 27.0 29.7 35.8 20 A2F100 1RA PVC05 0.09
20L M20 15.0 ½” 19.9 ¾” 8.7 14.0 27.0 29.7 34.3 20L A2F100 1RA PVC05 0.09
25 M25 15.0 ¾” 20.2 1″ 11.5 19.5 36.0 39.6 40.4 25 A2F100 1RA PVC09 0.16
25L M25 15.0 ¾” 20.2 1″ 14.0 20.0 36.0 39.6 39.9 25L A2F100 1RA PVC09 0.16
32 M32 15.0 1″ 25.0 1 ¼” 19.0 25.5 41.0 45.1 38.5 32 A2F100 1RA PVC10 0.18
32L M32 15.0 1″ 25.0 1 ¼” 20.2 26.3 41.0 45.1 35.5 32L A2F100 1RA PVC10 0.18
40 M40 15.0 1 ¼” 25.6 1 ½” 25.0 32.2 50.0 55.0 38.8 40 A2F100 1RA PVC13 0.25
50S M50 15.0 1 ½” 26.1 2″ 31.0 38.2 55.0 60.5 41.4 50S A2F100 1RA PVC15 0.33
50 M50 15.0 2″ 26.9 2 ½” 35.6 44.0 60.0 66.0 45.8 50 A2F100 1RA PVC18 0.35
63S M63 15.0 2″ 26.9 2 ½” 41.5 49.9 70.5 77.6 43.3 63S A2F100 1RA PVC21 0.56
63 M63 15.0 2 ½” 39.9 3″ 48.2 54.9 75.0 82.5 43.6 63 A2F100 1RA PVC23 0.55
75S M75 15.0 2 ½” 39.9 3″ 54.0 61.9 84.0 92.4 45.4 75S A2F100 1RA PVC26 0.73
75 M75 15.0 3″ 41.5 3 ½” 61.1 67.9 84.0 92.4 49.0 75 A2F100 1RA PVC26 0.58
90 M90 24.0 3 ½” 42.8 4″ 66.6 79.9 108.0 118.8 66.0 90 A2F100 1RA PVC31 1.71
100 M100 24.0 3½” 42.8 4″ 76.0 89.0 123.0 135.3 72.2 100 A2F100 1RA LSF33 2.26
115 M115 24.0 4″ 44.0 5″ 86.0 97.9 133.4 146.7 67.9 115 A2F100 1RA LSF34 2.74
130 M130 24.0 5″ 46.8 97.0 114.9 152.4 167.6 81.1 130 A2F100 1RA LSF35 4.07
Dimensions are displayed in millimetres unless otherwise stated

Imperial

Cable Gland Size Available Entry Threads “C”
(Alternate Metric Thread Lengths Available)
Overall Cable Diameter “A” Across Flats “D” Across Corners “D” Protrusion Length “F” Combined Ordering Reference
(*Brass Metric)
Shroud Cable
Gland Weight
(Ozs)
Standard Option
Metric Thread Length (Metric) “E” NPT Thread Length (NPT) “E” NPT Min Max Max Max Size Type Ordering Suffix
16 M16 0.59 0.13 0.31 0.94 1.04 1.37 16 A2F100 1RA PVC04 2.47
20S16 M20 0.59 ½” 0.78 ¾” 0.13 0.31 0.94 1.04 1.20 20S16 A2F100 1RA PVC04 2.82
20S M20 0.59 ½” 0.78 ¾” 0.26 0.44 0.94 1.04 1.26 20S A2F100 1RA PVC04 2.47
20 M20 0.59 ½” 0.78 ¾” 0.28 0.53 1.06 1.17 1.41 20 A2F100 1RA PVC05 3.17
20L M20 0.59 ½” 0.78 ¾” 0.34 0.55 1.06 1.17 1.35 20L A2F100 1RA PVC05 3.17
25 M25 0.59 ¾” 0.80 1″ 0.45 0.77 1.42 1.56 1.59 25 A2F100 1RA PVC09 5.64
25L M25 0.59 ¾” 0.80 1″ 0.55 0.79 1.42 1.56 1.57 25L A2F100 1RA PVC09 5.64
32 M32 0.59 1″ 0.98 1 ¼” 0.75 1.00 1.61 1.78 1.52 32 A2F100 1RA PVC10 6.35
32L M32 0.59 1″ 0.98 1 ¼” 0.80 1.04 1.61 1.78 1.40 32L A2F100 1RA PVC10 6.35
40 M40 0.59 1 ¼” 1.01 1 ½” 0.98 1.27 1.97 2.17 1.53 40 A2F100 1RA PVC13 8.82
50S M50 0.59 1 ½” 1.03 2″ 1.22 1.50 2.17 2.38 1.63 50S A2F100 1RA PVC15 11.64
50 M50 0.59 2″ 1.06 2 ½” 1.40 1.73 2.36 2.60 1.80 50 A2F100 1RA PVC18 12.35
63S M63 0.59 2″ 1.06 2 ½” 1.63 1.96 2.78 3.06 1.70 63S A2F100 1RA PVC21 19.75
63 M63 0.59 2 ½” 1.57 3″ 1.90 2.16 2.95 3.25 1.72 63 A2F100 1RA PVC23 19.40
75S M75 0.59 2 ½” 1.57 3″ 2.13 2.44 3.31 3.64 1.79 75S A2F100 1RA PVC26 25.75
75 M75 0.59 3″ 1.63 3 ½” 2.41 2.67 3.31 3.64 1.93 75 A2F100 1RA PVC26 20.46
90 M90 0.94 3 ½” 1.69 4″ 2.62 3.15 4.25 4.68 2.60 90 A2F100 1RA PVC31 60.32
100 M100 0.94 3½” 1.69 4″ 2.99 3.50 4.84 5.33 2.84 100 A2F100 1RA LSF33 79.72
115 M115 0.94 4″ 1.73 5″ 3.39 3.85 5.25 5.78 2.67 115 A2F100 1RA LSF34 96.65
130 M130 0.94 5″ 1.84 3.82 4.52 6.00 6.60 3.19 130 A2F100 1RA LSF35 143.57
Dimensions are displayed in inches unless otherwise stated

Download Spec Sheet

Download

Technical

Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications* Impact = Level 8, Retention = Class B
Enclosure Protection IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
ATEX Certificate SIRA16ATEX1018, SIRA16ATEX4020
Code of Protection II 2G, II 1D Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da
II 3G Ex nRc IIC Gc, I M2 Ex db I Mb, Ex eb I Mb
Compliance Standards EN 60079-0,1,7,15,31
IECEx Certificate IECEx SIR 16.0006
Code of Protection Ex db IIC Gb, Ex eb IIC Gb, Ex nRc IIC Gc, Ex ta IIIC Da, Ex db I Mb, Ex eb I Mb
Compliance Standards IEC 60079-0,1,7,15,31
RETIE Certificate 03866
Marine Approvals LRS: 01/00172, DNV: E-13848, ABS: 14-LD234401A-4-PDA
Ingress Protection Rating ** IP66, IP67 & IP68**
Deluge Protection Compliance DTS01 : 91
Cable Gland Material Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium
Seal Material CMP SOLO LSF Halogen Free Thermoset Elastomer
Cable Type Unarmoured & Braided
Sealing Technique CMP Unique Displacement Seal Concept
Sealing Area(s) Cable Outer Sheath
Optional Accessories Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
Optional Installation Tools Spanners

Product Table

Metric

Cable Gland Size Available Entry Threads “C”
(Alternate Metric Thread Lengths Available)
Overall Cable Diameter “A” Across Flats “D” Across Corners “D” Protrusion Length “F” Combined Ordering Reference
(*Brass Metric)
Shroud Cable
Gland Weight
(Kgs)
Standard Option
Metric Thread Length (Metric) “E” NPT Thread Length (NPT) “E” NPT Min Max Max Max Size Type Ordering Suffix
16 M16 15.0 3.2 8.0 24.0 26.4 34.9 16 A2F100 1RA PVC04 0.07
20S16 M20 15.0 ½” 19.9 ¾” 3.2 8.0 24.0 26.4 30.4 20S16 A2F100 1RA PVC04 0.08
20S M20 15.0 ½” 19.9 ¾” 6.5 11.2 24.0 26.4 31.9 20S A2F100 1RA PVC04 0.07
20 M20 15.0 ½” 19.9 ¾” 7.0 13.5 27.0 29.7 35.8 20 A2F100 1RA PVC05 0.09
20L M20 15.0 ½” 19.9 ¾” 8.7 14.0 27.0 29.7 34.3 20L A2F100 1RA PVC05 0.09
25 M25 15.0 ¾” 20.2 1″ 11.5 19.5 36.0 39.6 40.4 25 A2F100 1RA PVC09 0.16
25L M25 15.0 ¾” 20.2 1″ 14.0 20.0 36.0 39.6 39.9 25L A2F100 1RA PVC09 0.16
32 M32 15.0 1″ 25.0 1 ¼” 19.0 25.5 41.0 45.1 38.5 32 A2F100 1RA PVC10 0.18
32L M32 15.0 1″ 25.0 1 ¼” 20.2 26.3 41.0 45.1 35.5 32L A2F100 1RA PVC10 0.18
40 M40 15.0 1 ¼” 25.6 1 ½” 25.0 32.2 50.0 55.0 38.8 40 A2F100 1RA PVC13 0.25
50S M50 15.0 1 ½” 26.1 2″ 31.0 38.2 55.0 60.5 41.4 50S A2F100 1RA PVC15 0.33
50 M50 15.0 2″ 26.9 2 ½” 35.6 44.0 60.0 66.0 45.8 50 A2F100 1RA PVC18 0.35
63S M63 15.0 2″ 26.9 2 ½” 41.5 49.9 70.5 77.6 43.3 63S A2F100 1RA PVC21 0.56
63 M63 15.0 2 ½” 39.9 3″ 48.2 54.9 75.0 82.5 43.6 63 A2F100 1RA PVC23 0.55
75S M75 15.0 2 ½” 39.9 3″ 54.0 61.9 84.0 92.4 45.4 75S A2F100 1RA PVC26 0.73
75 M75 15.0 3″ 41.5 3 ½” 61.1 67.9 84.0 92.4 49.0 75 A2F100 1RA PVC26 0.58
90 M90 24.0 3 ½” 42.8 4″ 66.6 79.9 108.0 118.8 66.0 90 A2F100 1RA PVC31 1.71
100 M100 24.0 3½” 42.8 4″ 76.0 89.0 123.0 135.3 72.2 100 A2F100 1RA LSF33 2.26
115 M115 24.0 4″ 44.0 5″ 86.0 97.9 133.4 146.7 67.9 115 A2F100 1RA LSF34 2.74
130 M130 24.0 5″ 46.8 97.0 114.9 152.4 167.6 81.1 130 A2F100 1RA LSF35 4.07
Dimensions are displayed in millimetres unless otherwise stated

Imperial

Cable Gland Size Available Entry Threads “C”
(Alternate Metric Thread Lengths Available)
Overall Cable Diameter “A” Across Flats “D” Across Corners “D” Protrusion Length “F” Combined Ordering Reference
(*Brass Metric)
Shroud Cable
Gland Weight
(Ozs)
Standard Option
Metric Thread Length (Metric) “E” NPT Thread Length (NPT) “E” NPT Min Max Max Max Size Type Ordering Suffix
16 M16 0.59 0.13 0.31 0.94 1.04 1.37 16 A2F100 1RA PVC04 2.47
20S16 M20 0.59 ½” 0.78 ¾” 0.13 0.31 0.94 1.04 1.20 20S16 A2F100 1RA PVC04 2.82
20S M20 0.59 ½” 0.78 ¾” 0.26 0.44 0.94 1.04 1.26 20S A2F100 1RA PVC04 2.47
20 M20 0.59 ½” 0.78 ¾” 0.28 0.53 1.06 1.17 1.41 20 A2F100 1RA PVC05 3.17
20L M20 0.59 ½” 0.78 ¾” 0.34 0.55 1.06 1.17 1.35 20L A2F100 1RA PVC05 3.17
25 M25 0.59 ¾” 0.80 1″ 0.45 0.77 1.42 1.56 1.59 25 A2F100 1RA PVC09 5.64
25L M25 0.59 ¾” 0.80 1″ 0.55 0.79 1.42 1.56 1.57 25L A2F100 1RA PVC09 5.64
32 M32 0.59 1″ 0.98 1 ¼” 0.75 1.00 1.61 1.78 1.52 32 A2F100 1RA PVC10 6.35
32L M32 0.59 1″ 0.98 1 ¼” 0.80 1.04 1.61 1.78 1.40 32L A2F100 1RA PVC10 6.35
40 M40 0.59 1 ¼” 1.01 1 ½” 0.98 1.27 1.97 2.17 1.53 40 A2F100 1RA PVC13 8.82
50S M50 0.59 1 ½” 1.03 2″ 1.22 1.50 2.17 2.38 1.63 50S A2F100 1RA PVC15 11.64
50 M50 0.59 2″ 1.06 2 ½” 1.40 1.73 2.36 2.60 1.80 50 A2F100 1RA PVC18 12.35
63S M63 0.59 2″ 1.06 2 ½” 1.63 1.96 2.78 3.06 1.70 63S A2F100 1RA PVC21 19.75
63 M63 0.59 2 ½” 1.57 3″ 1.90 2.16 2.95 3.25 1.72 63 A2F100 1RA PVC23 19.40
75S M75 0.59 2 ½” 1.57 3″ 2.13 2.44 3.31 3.64 1.79 75S A2F100 1RA PVC26 25.75
75 M75 0.59 3″ 1.63 3 ½” 2.41 2.67 3.31 3.64 1.93 75 A2F100 1RA PVC26 20.46
90 M90 0.94 3 ½” 1.69 4″ 2.62 3.15 4.25 4.68 2.60 90 A2F100 1RA PVC31 60.32
100 M100 0.94 3½” 1.69 4″ 2.99 3.50 4.84 5.33 2.84 100 A2F100 1RA LSF33 79.72
115 M115 0.94 4″ 1.73 5″ 3.39 3.85 5.25 5.78 2.67 115 A2F100 1RA LSF34 96.65
130 M130 0.94 5″ 1.84 3.82 4.52 6.00 6.60 3.19 130 A2F100 1RA LSF35 143.57
Dimensions are displayed in inches unless otherwise stated