Products > BS6724 0.6/1Kv LSZH

BS6724 0.6/1Kv LSZH

Description

Product Table

SCHEDULE OF GUARANTEED CHARACTERISTICS FOR XLPE INSULATED, GALVANISED ROUND STEEL WIRE ARMORED AND LSOH SHEATHED CABLES

   

Manufacturer

Türk Prysmian

Türk Prysmian

Türk Prysmian

Symbol of the cable

2XRH 2×1.5mm2

2XRH 2×2,5mm2

2XRH 2x4mm2

Standards

BS 6724

BS 6724

BS 6724

Nominal voltages (V)

0,6/1

0,6/1

0,6/1

CONSTRUCTIONAL REQUIREMENTS

Conductor Type

IEC 60228 Class 2

IEC 60228 Class 2

IEC 60228 Class 2

Material

Copper

Copper

Copper

Nominal cross-sectional area (mm2)

1,5

2,5

4

Shape

Circular, Stranded

Circular, Stranded

Circular, Stranded

Insulation Material Thickness (mm)

XLPE

XLPE

XLPE

Thickness (mm)

0,7

0,7

0,7

Filler Material

Rubber-like material

Rubber-like material

Rubber-like material

Inner Covering Material

LSOH Compound

LSOH Compound

LSOH Compound

Diameter

8,5

9,4

10,4

Armor Material

Galvanized round steel wires

Galvanized round steel wires

Galvanized round steel wires

Diameter of wires (mm)

0,9

0,9

0,9

Outer Sheath Material

LSOH Compound

LSOH Compound

LSOH Compound

Minimum thickness at any point (mm)

0,84

0,92

0,92

Color

Black

Black

Black

ELECTRICAL CHARACTERISTICS

Max. Contionus operation temperature of conductors (°C)

90

90

90

Max. Conductor temperature during short circuit (°C)

250

250

250

Max. Short circuit current of conductors for 1 sec. (kA)

0,358

0,572

0,572

Max. D.C. resistance of conductor at 20°C (Ohm/km)

12,1

7,41

4,61

OTHER REQUIREMENTS

External diameter approx (mm)

13,5

14,5

15,5

Weight of cable approx (kg/km)

328

380

448

Min. bending radius (mm)

12x overall cable diameter

12x overall cable diameter

12x overall cable diameter

Recomended Minimum laying temperature of cable

+2

+2

+2

Max. Pulling force (with pulling head attached to conductors (N)

150

250

400

Flame retardancy

IEC 60332-3-24 CAT. C

IEC 60332-3-24 CAT. C

IEC 60332-3-24 CAT. C

Colour of cores

Grey-Black-Brown

Grey-Black-Brown

Grey-Black-Brown

Marking: Emboosed

PRYSMIAN ELECTRIC CABLE 2XRH 3×4 600/1000 V YEAR of MANUFACTUER

METER MARKING

Information and data contained in the chart are prepared with due diligince and long analysis, accuracy of which is guaranteed within the integrity of whole information and data. Even the tiniest amendment will trigger repetition of the same procedure. Therefore, if a change is requested on data, you are requested to apply to Prysmian with such request, drawing spesific attention to the planned changes. Upon which Prysmian shall approve in writing by repeating the same analysis procedure. Prysmian, shall not be held liable from changes made unilaterally, without following the due procedure. No action by Prysmian, shall be construed as implicit approval to such changes.

SCHEDULE OF GUARANTEED CHARACTERISTICS FOR XLPE INSULATED, GALVANISED ROUND STEEL WIRE ARMORED AND LSOH SHEATHED CABLES

Manufacturer

Türk Prysmian

Türk Prysmian

Türk Prysmian

Türk Prysmian

Symbol of the cable

2XRH 3×1.5mm2

2XRH 3×2,5mm2

2XRH 3x4mm2

2XRH 3x16mm2

Standards

BS 6724

BS 6724

BS 6724

BS 6724

Nominal voltages (V)

0,6/1

0,6/1

0,6/1

0,6/1

CONSTRUCTIONAL REQUIREMENTS

Conductor Type

IEC 60228 Class 2

IEC 60228 Class 2

IEC 60228 Class 2

 

Material

Copper

Copper

Copper

Copper

Nominal cross-sectional area (mm2)

1,5

2,5

4

16

Shape

Circular, Stranded

Circular, Stranded

Circular, Stranded

Circular, Stranded

Insulation Material Thickness (mm)

XLPE

XLPE

XLPE

XLPE

Thickness (mm)

0,7

0,7

0,7

0,7

Filler Material

Rubber-like material

Rubber-like material

Rubber-like material

Rubber-like material

Inner Covering Material

LSOH Compound

LSOH Compound

LSOH Compound

 

Diameter

9

9,9

11

16,3

Armor Material

Galvanized round steel wires

Galvanized round steel wires

Galvanized round steel wires

Galvanized round steel wires

Diameter of wires (mm)

0,9

0,9

0,9

1,25

Outer Sheath Material

LSOH Compound

LSOH Compound

LSOH Compound

LSOH Compound

Minimum thickness at any point (mm)

0,84

0,92

0,92

1,08

Color

Black

Black

Black

Black

ELECTRICAL CHARACTERISTICS

Max. Contionus operation temperature of conductors (°C)

90

90

90

90

Max. Conductor temperature during short circuit (°C)

250

250

250

250

Max. Short circuit current of conductors for 1 sec. (kA)

0,358

0,572

0,572

2,29

Max. D.C. resistance of conductor at 20°C (Ohm/km)

7,41

4,61

4,61

1,15

OTHER REQUIREMENTS

External diameter approx (mm)

15

16

17

23

Weight of cable approx (kg/km)

370

430

510

1172

Min. bending radius (mm)

12x overall cable diameter

12x overall cable diameter

12x overall cable diameter

12x overall cable diameter

Recomended Minimum laying temperature of cable

+2

+2

+2

 

Max. Pulling force (with pulling head attached to conductors (N)

225

375

600

2400

Flame retardancy

IEC 60332-3-24 CAT. C

IEC 60332-3-24 CAT. C

IEC 60332-3-24 CAT. C

IEC 60332-3-24 CAT. C

Colour of cores

Grey-Black-Brown

Grey-Black-Brown

Grey-Black-Brown

Grey-Black-Brown

Marking: Emboosed

PRYSMIAN ELECTRIC CABLE 2XRH 3×4 600/1000 V YEAR of MANUFACTUER

METER MARKING

Information and data contained in the chart are prepared with due diligince and long analysis, accuracy of which is guaranteed within the integrity of whole information and data. Even the tiniest amendment will trigger repetition of the same procedure. Therefore, if a change is requested on data, you are requested to apply to Prysmian with such request, drawing spesific attention to the planned changes. Upon which Prysmian shall approve in writing by repeating the same analysis procedure. Prysmian, shall not be held liable from changes made unilaterally, without following the due procedure. No action by Prysmian, shall be construed as implicit approval to such changes.

Download Spec Sheet

Download

Control Panel Heat Dissipation Calculator
Cable Sizing / Maximum Distance Calculator

Product Table

SCHEDULE OF GUARANTEED CHARACTERISTICS FOR XLPE INSULATED, GALVANISED ROUND STEEL WIRE ARMORED AND LSOH SHEATHED CABLES

   

Manufacturer

Türk Prysmian

Türk Prysmian

Türk Prysmian

Symbol of the cable

2XRH 2×1.5mm2

2XRH 2×2,5mm2

2XRH 2x4mm2

Standards

BS 6724

BS 6724

BS 6724

Nominal voltages (V)

0,6/1

0,6/1

0,6/1

CONSTRUCTIONAL REQUIREMENTS

Conductor Type

IEC 60228 Class 2

IEC 60228 Class 2

IEC 60228 Class 2

Material

Copper

Copper

Copper

Nominal cross-sectional area (mm2)

1,5

2,5

4

Shape

Circular, Stranded

Circular, Stranded

Circular, Stranded

Insulation Material Thickness (mm)

XLPE

XLPE

XLPE

Thickness (mm)

0,7

0,7

0,7

Filler Material

Rubber-like material

Rubber-like material

Rubber-like material

Inner Covering Material

LSOH Compound

LSOH Compound

LSOH Compound

Diameter

8,5

9,4

10,4

Armor Material

Galvanized round steel wires

Galvanized round steel wires

Galvanized round steel wires

Diameter of wires (mm)

0,9

0,9

0,9

Outer Sheath Material

LSOH Compound

LSOH Compound

LSOH Compound

Minimum thickness at any point (mm)

0,84

0,92

0,92

Color

Black

Black

Black

ELECTRICAL CHARACTERISTICS

Max. Contionus operation temperature of conductors (°C)

90

90

90

Max. Conductor temperature during short circuit (°C)

250

250

250

Max. Short circuit current of conductors for 1 sec. (kA)

0,358

0,572

0,572

Max. D.C. resistance of conductor at 20°C (Ohm/km)

12,1

7,41

4,61

OTHER REQUIREMENTS

External diameter approx (mm)

13,5

14,5

15,5

Weight of cable approx (kg/km)

328

380

448

Min. bending radius (mm)

12x overall cable diameter

12x overall cable diameter

12x overall cable diameter

Recomended Minimum laying temperature of cable

+2

+2

+2

Max. Pulling force (with pulling head attached to conductors (N)

150

250

400

Flame retardancy

IEC 60332-3-24 CAT. C

IEC 60332-3-24 CAT. C

IEC 60332-3-24 CAT. C

Colour of cores

Grey-Black-Brown

Grey-Black-Brown

Grey-Black-Brown

Marking: Emboosed

PRYSMIAN ELECTRIC CABLE 2XRH 3×4 600/1000 V YEAR of MANUFACTUER

METER MARKING

Information and data contained in the chart are prepared with due diligince and long analysis, accuracy of which is guaranteed within the integrity of whole information and data. Even the tiniest amendment will trigger repetition of the same procedure. Therefore, if a change is requested on data, you are requested to apply to Prysmian with such request, drawing spesific attention to the planned changes. Upon which Prysmian shall approve in writing by repeating the same analysis procedure. Prysmian, shall not be held liable from changes made unilaterally, without following the due procedure. No action by Prysmian, shall be construed as implicit approval to such changes.

SCHEDULE OF GUARANTEED CHARACTERISTICS FOR XLPE INSULATED, GALVANISED ROUND STEEL WIRE ARMORED AND LSOH SHEATHED CABLES

Manufacturer

Türk Prysmian

Türk Prysmian

Türk Prysmian

Türk Prysmian

Symbol of the cable

2XRH 3×1.5mm2

2XRH 3×2,5mm2

2XRH 3x4mm2

2XRH 3x16mm2

Standards

BS 6724

BS 6724

BS 6724

BS 6724

Nominal voltages (V)

0,6/1

0,6/1

0,6/1

0,6/1

CONSTRUCTIONAL REQUIREMENTS

Conductor Type

IEC 60228 Class 2

IEC 60228 Class 2

IEC 60228 Class 2

 

Material

Copper

Copper

Copper

Copper

Nominal cross-sectional area (mm2)

1,5

2,5

4

16

Shape

Circular, Stranded

Circular, Stranded

Circular, Stranded

Circular, Stranded

Insulation Material Thickness (mm)

XLPE

XLPE

XLPE

XLPE

Thickness (mm)

0,7

0,7

0,7

0,7

Filler Material

Rubber-like material

Rubber-like material

Rubber-like material

Rubber-like material

Inner Covering Material

LSOH Compound

LSOH Compound

LSOH Compound

 

Diameter

9

9,9

11

16,3

Armor Material

Galvanized round steel wires

Galvanized round steel wires

Galvanized round steel wires

Galvanized round steel wires

Diameter of wires (mm)

0,9

0,9

0,9

1,25

Outer Sheath Material

LSOH Compound

LSOH Compound

LSOH Compound

LSOH Compound

Minimum thickness at any point (mm)

0,84

0,92

0,92

1,08

Color

Black

Black

Black

Black

ELECTRICAL CHARACTERISTICS

Max. Contionus operation temperature of conductors (°C)

90

90

90

90

Max. Conductor temperature during short circuit (°C)

250

250

250

250

Max. Short circuit current of conductors for 1 sec. (kA)

0,358

0,572

0,572

2,29

Max. D.C. resistance of conductor at 20°C (Ohm/km)

7,41

4,61

4,61

1,15

OTHER REQUIREMENTS

External diameter approx (mm)

15

16

17

23

Weight of cable approx (kg/km)

370

430

510

1172

Min. bending radius (mm)

12x overall cable diameter

12x overall cable diameter

12x overall cable diameter

12x overall cable diameter

Recomended Minimum laying temperature of cable

+2

+2

+2

 

Max. Pulling force (with pulling head attached to conductors (N)

225

375

600

2400

Flame retardancy

IEC 60332-3-24 CAT. C

IEC 60332-3-24 CAT. C

IEC 60332-3-24 CAT. C

IEC 60332-3-24 CAT. C

Colour of cores

Grey-Black-Brown

Grey-Black-Brown

Grey-Black-Brown

Grey-Black-Brown

Marking: Emboosed

PRYSMIAN ELECTRIC CABLE 2XRH 3×4 600/1000 V YEAR of MANUFACTUER

METER MARKING

Information and data contained in the chart are prepared with due diligince and long analysis, accuracy of which is guaranteed within the integrity of whole information and data. Even the tiniest amendment will trigger repetition of the same procedure. Therefore, if a change is requested on data, you are requested to apply to Prysmian with such request, drawing spesific attention to the planned changes. Upon which Prysmian shall approve in writing by repeating the same analysis procedure. Prysmian, shall not be held liable from changes made unilaterally, without following the due procedure. No action by Prysmian, shall be construed as implicit approval to such changes.