Products > C2KGP Cable Gland – Industrial/General Purpose

C2KGP Cable Gland – Industrial/General Purpose

Single Seal Industrial Cable Gland

• High quality durable materials
• Robust, heavy duty design
• Metal-to-metal armour clamping
• Direct & remote installation
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Integral protected deluge seal
• -60°C to +130°C
• EMC tested

Note: † Grooved Cone (X) is predominantly used for Wire Braid (e.g. GSWB, TCWB), Steel Tape Armour (STA, DSTA) and Aluminium Strip Armour (ASA) but is also suitable for Single Wire Armour (SWA), Aluminium Wire Armour (AWA) and Pliable Wire Armour (PWA) if the range is outside that of the Stepped Cone (W).

Note: Grooved Cone (X) dimensions shown in the Cable Gland Selection Table below are for a double wire strand of braid armour cables. Tapes can also be doubled over. For cables that have only a single layer of armour such as SWA the clamping range should be used as shown in the table below.

Stepped (W) Cone is suitable for Single Wire Armour (SWA), or Aluminium Wire Armour (AWA) cables.

For under / oversized armour wires

For all types of Armoured Cables

Description

C2KGP Cable Gland Technical Info

 

Design SpecificationBS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications *Impact = Level 8, Retention = Class D
Enclosure ProtectionIK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
Electrical Classifications *Category B (Category A when used with braid, tape or pliable wire armour cables)
GOST R CertificatePOCC.GB.35.H00102
Marine ApprovalsLRS: 01/00171 (E1)
Ingress Protection Rating **IP66, IP67 & IP68
Deluge Protection ComplianceDTS01 : 91
Cable Gland MaterialBrass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium
Seal MaterialCMP Thermoset Rubber
Cable TypeSingle Wire Armour (SWA), Aluminium Wire Armour (AWA), Steel Tape Armour (STA), Aluminium Strip Armour (ASA), Wire Braid Armour, Screened Flexible (EMC) Wire Braid (e.g. CY / SY), Pliable Wire Armour (PWA)
Armour ClampingReversible Armour Cone & AnyWay Universal Clamping Ring
Sealing TechniqueUnique CMP ‘LRS’ Outer Seal (Load Retention Seal)
Sealing Area(s)Cable Outer Sheath
Optional AccessoriesLocknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
Optional Installation ToolsSpanners, Armour Former Tool

Product Table

Metric

Cable Gland SizeAvailable Entry Threads “C” (Alternate Metric Thread Lengths Available)Cable
Bedding
Diameter
“A”
Overall
Cable
Diameter
“B”
Armour RangeAcross
Flats “D”
Across
Corners
“D”
Protrusion
Length “F”
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Kgs)
Grooved Cone (X)Stepped Cone (W)
MetricThread Length
(Metric) “E”
MaxMaxMaxMinMaxMaxMaxMaxMaxSizeTypeOrdering
Suffix
20S16M2010.08.76.113.10.31.00.81.2530.533.665.020S16C2KGP1RAPVC060.23
20SM2010.011.79.515.90.31.00.81.2530.533.662.020SC2KGP1RAPVC060.22
20M2010.014.012.520.90.41.00.81.2530.533.663.020C2KGP1RAPVC060.22
25SM2510.020.014.022.00.41.21.251.637.541.369.525SC2KGP1RAPVC090.35
25M2510.020.018.226.20.41.21.251.637.541.369.525C2KGP1RAPVC090.35
32M3210.026.323.733.90.41.21.62.046.050.675.032C2KGP1RAPVC110.55
40M4015.032.227.940.40.41.61.62.055.060.575.040C2KGP1RAPVC150.75
50SM5015.038.235.246.70.41.62.02.560.066.077.050SC2KGP1RAPVC180.86
50M5015.044.140.453.00.61.62.02.570.177.177.050C2KGP1RAPVC211.13
63SM6315.050.045.659.40.61.62.02.575.082.580.063SC2KGP1RAPVC231.33
63M6315.056.054.665.80.61.62.02.580.088.080.063C2KGP1RAPVC251.34
75SM7515.062.059.072.00.61.62.02.590.099.087.075SC2KGP1RAPVC282.02
75M7515.068.066.778.40.61.62.53.0100.0100.088.075C2KGP1RAPVC302.48
90M9024.080.076.290.30.81.63.154.0115.0115.0102.090C2KGP1RAPVC323.52
100M10024.091.086.1101.40.81.63.154.0127.0127.0114.0100C2KGP1RALSF334.57
115M11524.098.0101.5110.20.81.63.154.0133.4133.4114.0115C2KGP1RALSF346.50
130M13024.0115.0110.2123.20.81.63.154.0152.4152.4114.0130C2KGP1RALSF358.50
Dimensions displayed in millimeters unless otherwise stated

Imperial

Cable Gland SizeAvailable Entry Threads “C” (Alternate Metric Thread Lengths Available)Cable
Bedding
Diameter
“A”
Overall
Cable
Diameter
“B”
Armour RangeAcross
Flats “D”
Across
Corners
“D”
Protrusion
Length “F”
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Ozs)
Grooved Cone (X)Stepped Cone (W)
MetricThread Length
(Metric) “E”
MaxMaxMaxMinMaxMaxMaxMaxMaxSizeTypeOrdering
Suffix
20S16M200.390.340.240.520.010.040.030.051.201.322.5620S16C2KGP1RAPVC068.11
20SM200.390.460.370.630.010.040.030.051.201.322.4420SC2KGP1RAPVC067.76
20M200.390.550.490.820.020.040.030.051.201.322.4820C2KGP1RAPVC067.76
25SM250.390.790.550.870.020.050.050.061.481.632.7425SC2KGP1RAPVC0912.35
25M250.390.790.721.030.020.050.050.061.481.632.7425C2KGP1RAPVC0912.35
32M320.391.040.931.330.020.050.060.081.811.992.9532C2KGP1RAPVC1119.40
40M400.591.271.101.590.020.060.060.082.172.382.9540C2KGP1RAPVC1526.46
50SM500.591.501.391.840.020.060.080.102.362.603.0350SC2KGP1RAPVC1830.34
50M500.591.741.592.090.020.060.080.102.763.043.0350C2KGP1RAPVC2139.86
63SM630.591.971.802.340.020.060.080.102.953.253.1563SC2KGP1RAPVC2346.91
63M630.592.202.152.590.020.060.080.103.153.463.1563C2KGP1RAPVC2547.27
75SM750.592.442.322.830.020.060.080.103.543.903.4375SC2KGP1RAPVC2871.25
75M750.592.682.633.090.020.060.100.123.943.943.4675C2KGP1RAPVC3087.48
90M900.943.153.003.560.030.060.120.164.534.534.0290C2KGP1RAPVC32124.16
100M1000.943.583.393.990.030.060.120.165.005.004.49100C2KGP1RALSF33161.20
115M1150.943.864.004.340.030.060.120.165.255.254.49115C2KGP1RALSF34229.28
130M1300.944.534.344.850.030.060.120.166.006.004.49130C2KGP1RALSF35299.83
Dimensions displayed in inches unless otherwise stated

Download Spec Sheet

Download

C2KGP Cable Gland Technical Info

 

Design SpecificationBS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications *Impact = Level 8, Retention = Class D
Enclosure ProtectionIK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
Electrical Classifications *Category B (Category A when used with braid, tape or pliable wire armour cables)
GOST R CertificatePOCC.GB.35.H00102
Marine ApprovalsLRS: 01/00171 (E1)
Ingress Protection Rating **IP66, IP67 & IP68
Deluge Protection ComplianceDTS01 : 91
Cable Gland MaterialBrass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium
Seal MaterialCMP Thermoset Rubber
Cable TypeSingle Wire Armour (SWA), Aluminium Wire Armour (AWA), Steel Tape Armour (STA), Aluminium Strip Armour (ASA), Wire Braid Armour, Screened Flexible (EMC) Wire Braid (e.g. CY / SY), Pliable Wire Armour (PWA)
Armour ClampingReversible Armour Cone & AnyWay Universal Clamping Ring
Sealing TechniqueUnique CMP ‘LRS’ Outer Seal (Load Retention Seal)
Sealing Area(s)Cable Outer Sheath
Optional AccessoriesLocknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
Optional Installation ToolsSpanners, Armour Former Tool

Product Table

Metric

Cable Gland SizeAvailable Entry Threads “C” (Alternate Metric Thread Lengths Available)Cable
Bedding
Diameter
“A”
Overall
Cable
Diameter
“B”
Armour RangeAcross
Flats “D”
Across
Corners
“D”
Protrusion
Length “F”
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Kgs)
Grooved Cone (X)Stepped Cone (W)
MetricThread Length
(Metric) “E”
MaxMaxMaxMinMaxMaxMaxMaxMaxSizeTypeOrdering
Suffix
20S16M2010.08.76.113.10.31.00.81.2530.533.665.020S16C2KGP1RAPVC060.23
20SM2010.011.79.515.90.31.00.81.2530.533.662.020SC2KGP1RAPVC060.22
20M2010.014.012.520.90.41.00.81.2530.533.663.020C2KGP1RAPVC060.22
25SM2510.020.014.022.00.41.21.251.637.541.369.525SC2KGP1RAPVC090.35
25M2510.020.018.226.20.41.21.251.637.541.369.525C2KGP1RAPVC090.35
32M3210.026.323.733.90.41.21.62.046.050.675.032C2KGP1RAPVC110.55
40M4015.032.227.940.40.41.61.62.055.060.575.040C2KGP1RAPVC150.75
50SM5015.038.235.246.70.41.62.02.560.066.077.050SC2KGP1RAPVC180.86
50M5015.044.140.453.00.61.62.02.570.177.177.050C2KGP1RAPVC211.13
63SM6315.050.045.659.40.61.62.02.575.082.580.063SC2KGP1RAPVC231.33
63M6315.056.054.665.80.61.62.02.580.088.080.063C2KGP1RAPVC251.34
75SM7515.062.059.072.00.61.62.02.590.099.087.075SC2KGP1RAPVC282.02
75M7515.068.066.778.40.61.62.53.0100.0100.088.075C2KGP1RAPVC302.48
90M9024.080.076.290.30.81.63.154.0115.0115.0102.090C2KGP1RAPVC323.52
100M10024.091.086.1101.40.81.63.154.0127.0127.0114.0100C2KGP1RALSF334.57
115M11524.098.0101.5110.20.81.63.154.0133.4133.4114.0115C2KGP1RALSF346.50
130M13024.0115.0110.2123.20.81.63.154.0152.4152.4114.0130C2KGP1RALSF358.50
Dimensions displayed in millimeters unless otherwise stated

Imperial

Cable Gland SizeAvailable Entry Threads “C” (Alternate Metric Thread Lengths Available)Cable
Bedding
Diameter
“A”
Overall
Cable
Diameter
“B”
Armour RangeAcross
Flats “D”
Across
Corners
“D”
Protrusion
Length “F”
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Ozs)
Grooved Cone (X)Stepped Cone (W)
MetricThread Length
(Metric) “E”
MaxMaxMaxMinMaxMaxMaxMaxMaxSizeTypeOrdering
Suffix
20S16M200.390.340.240.520.010.040.030.051.201.322.5620S16C2KGP1RAPVC068.11
20SM200.390.460.370.630.010.040.030.051.201.322.4420SC2KGP1RAPVC067.76
20M200.390.550.490.820.020.040.030.051.201.322.4820C2KGP1RAPVC067.76
25SM250.390.790.550.870.020.050.050.061.481.632.7425SC2KGP1RAPVC0912.35
25M250.390.790.721.030.020.050.050.061.481.632.7425C2KGP1RAPVC0912.35
32M320.391.040.931.330.020.050.060.081.811.992.9532C2KGP1RAPVC1119.40
40M400.591.271.101.590.020.060.060.082.172.382.9540C2KGP1RAPVC1526.46
50SM500.591.501.391.840.020.060.080.102.362.603.0350SC2KGP1RAPVC1830.34
50M500.591.741.592.090.020.060.080.102.763.043.0350C2KGP1RAPVC2139.86
63SM630.591.971.802.340.020.060.080.102.953.253.1563SC2KGP1RAPVC2346.91
63M630.592.202.152.590.020.060.080.103.153.463.1563C2KGP1RAPVC2547.27
75SM750.592.442.322.830.020.060.080.103.543.903.4375SC2KGP1RAPVC2871.25
75M750.592.682.633.090.020.060.100.123.943.943.4675C2KGP1RAPVC3087.48
90M900.943.153.003.560.030.060.120.164.534.534.0290C2KGP1RAPVC32124.16
100M1000.943.583.393.990.030.060.120.165.005.004.49100C2KGP1RALSF33161.20
115M1150.943.864.004.340.030.060.120.165.255.254.49115C2KGP1RALSF34229.28
130M1300.944.534.344.850.030.060.120.166.006.004.49130C2KGP1RALSF35299.83
Dimensions displayed in inches unless otherwise stated