Products > E1W SOLO Cable Gland
industrial / general purpose double seal cable gland solo lsf gland

E1W SOLO Cable Gland
industrial / general purpose double seal cable gland solo lsf gland

Industrial Double Seal Cable Gland SOLO LSF Kit
• Metal-to-metal armour clamping
• Direct & remote installation
• Displacement type inner seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Deluge protection option
• -60°C to +130°C
• EMC tested
• LUL (London Underground) approved

For under / oversized armour wires

For all types of Steel & Aluminium Wire Armoured Cables

Description

Technical

TypeE1W SOLO-Kit
Design SpecificationBS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications*Impact = Level 8, Retention = Class D
Enclosure ProtectionIK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
Electrical Classifications *Category B
Marine ApprovalsLRS: 01/00171 (E1), ABS: 16-LD1472056-PDA
Ingress Protection Rating **IP66 as standard (IP67, IP68 available upon request)
Cable Gland MaterialBrass, Electroless Nickel Plated Brass, Aluminium
Seal MaterialCMP SOLO LSF Halogen Free Thermoset Elastomer
Cable TypeSingle Wire Armour (SWA), Aluminium Wire Armour (AWA)
Armour ClampingDetachable Armour Cone & AnyWay Universal Clamping Ring
Sealing TechniqueCMP Inner Displacement Seal & Unique CMP ‘LRS’™ Outer Load Retention Seal
Sealing Area(s)Cable Inner Bedding & Outer Cable Sheath
Cable Gland Kits AvailableUp to & including size 25 – 2 glands, 2 locknuts, 2 earth tags & 2 LSF shrouds
Size 32 & above – 1 gland, 1 locknut, 1 earth tag & 1 LSF shroud
Optional AccessoriesLocknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
Optional Installation ToolsSpanners, Armour Former Tool

Product Table

Metric

Cable Gland SizeAvailable Entry Threads “C” (Alternate Metric Thread Lengths Available)Cable
Bedding
Diameter
“A”
Overall
Cable
Diameter
“B”
Armour RangeAcross
Flats
“D”
Across
Corners
“D”
Protrusion
Length “F”
(Without Shroud)
Combined Ordering Reference
(*Brass Metric)
Cable
Gland Only
Weight
(Kgs)
StandardOption
MetricThread Length (Metric) “E”NPTThread Length
(NPT) “E”
NPTMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20s16M2010.01/2″19.93/4″3.18.66.113.10.81.2524.026.472.520S16E1WLSF2RA0.16
20SM2010.01/2″19.93/4″6.111.69.515.90.81.2524.026.470.020SE1WLSF2RA0.15
20M2010.01/2″19.93/4″6.513.912.520.90.81.2530.533.673.020E1WLSF2RA0.21
25SM2510.03/4″20.21″11.119.914.022.01.251.637.541.389.025SE1WLSF2RA0.33
25M2510.03/4″20.21″11.119.918.226.21.251.637.541.389.025E1WLSF2RA0.33
32M3210.01″25.01 1/4″17.026.223.733.91.62.046.050.686.032E1WLSF2RA0.43
40M4015.01 1/4″25.61 1/2″22.032.127.940.41.62.055.060.590.040E1WLSF2RA0.62
50SM5015.01 1/2″26.12″29.538.135.246.72.02.560.066.091.050SE1WLSF2RA0.75
50M5015.02″26.92 1/2″35.644.040.453.02.02.570.177.195.050E1WLSF2RA0.95
63SM6315.02″26.92 1/2″40.149.945.659.42.02.575.082.5102.063SE1WLSF2RA1.34
63M6315.02 1/2″39.93″47.255.954.665.82.02.580.088.0104.063E1WLSF2RA1.34
75SM7515.02 1/2″39.93″52.861.959.072.02.02.590.099.0115.075SE1WLSF2RA2.11
75M7515.03″41.53 1/2″59.167.966.778.42.53.0100.0110.0117.075E1WLSF2RA2.42
90M9024.03 1/2″42.84″66.678.676.290.33.154.0114.3125.4147.090E1WLSF2RA4.21
100M10024.04″44.05″76.090.986.1101.43.154.0123.0135.3140.0100E1WLSF2RA4.45
115M11524.04″44.05″86.097.9101.5110.23.154.0133.4146.7162.0115E1WLSF2RA6.19
130M13024.05″46.86″97.0114.9110.2123.23.154.0152.4167.6174.0130E1WLSF2RA8.34
Dimensions displayed in millimeters unless otherwise stated

Imperial

Cable Gland SizeAvailable Entry Threads “C” (Alternate Metric Thread Lengths Available)Cable
Bedding
Diameter
“A”
Overall
Cable
Diameter
“B”
Armour RangeAcross
Flats
“D”
Across
Corners
“D”
Protrusion
Length “F”
(Without Shroud)
Combined Ordering Reference
(*Brass Metric)
Cable
Gland Only
Weight
(Ozs)
StandardOption
MetricThread Length (Metric) “E”NPTThread Length
(NPT) “E”
NPTMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20s16M200.391/2″0.783/4″0.120.340.240.520.030.050.941.042.8520S16E1WLSF2RA5.75
20SM200.391/2″0.783/4″0.240.460.370.630.030.050.941.042.7620SE1WLSF2RA5.29
20M200.391/2″0.783/4″0.260.550.490.820.030.051.201.322.8720E1WLSF2RA7.41
25SM250.393/4″0.801″0.440.780.550.870.050.061.481.633.5025SE1WLSF2RA11.64
25M250.393/4″0.801″0.440.780.721.030.050.061.481.633.5025E1WLSF2RA11.64
32M320.391″0.981 1/4″0.671.030.931.330.060.081.811.993.3932E1WLSF2RA15.17
40M400.591 1/4″1.011 1/2″0.871.261.101.590.060.082.172.383.5440E1WLSF2RA21.87
50SM500.591 1/2″1.032″1.161.501.391.840.080.102.362.603.5850SE1WLSF2RA26.46
50M500.592″1.062 1/2″1.401.731.592.090.080.102.763.043.7450E1WLSF2RA33.51
63SM630.592″1.062 1/2″1.581.961.802.340.080.102.953.254.0263SE1WLSF2RA47.27
63M630.592 1/2″1.573″1.862.22.152.590.080.103.153.464.0963E1WLSF2RA47.27
75SM750.592 1/2″1.573″2.082.442.322.830.080.103.543.904.5375SE1WLSF2RA74.43
75M750.593″1.633 1/2″2.332.672.633.090.100.123.944.334.6175E1WLSF2RA85.36
90M900.943 1/2″1.694″2.623.093.003.560.120.164.504.945.7990E1WLSF2RA148.5
100M1000.944″1.735″2.993.583.393.990.120.164.845.335.51100E1WLSF2RA156.97
115M1150.944″1.735″3.393.854.004.340.120.165.255.786.38115E1WLSF2RA218.35
130M1300.945″1.846″3.824.524.344.850.120.166.006.606.85130E1WLSF2RA294.19
Dimensions displayed in inches unless otherwise stated

Download Spec Sheet

Download

Technical

TypeE1W SOLO-Kit
Design SpecificationBS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications*Impact = Level 8, Retention = Class D
Enclosure ProtectionIK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
Electrical Classifications *Category B
Marine ApprovalsLRS: 01/00171 (E1), ABS: 16-LD1472056-PDA
Ingress Protection Rating **IP66 as standard (IP67, IP68 available upon request)
Cable Gland MaterialBrass, Electroless Nickel Plated Brass, Aluminium
Seal MaterialCMP SOLO LSF Halogen Free Thermoset Elastomer
Cable TypeSingle Wire Armour (SWA), Aluminium Wire Armour (AWA)
Armour ClampingDetachable Armour Cone & AnyWay Universal Clamping Ring
Sealing TechniqueCMP Inner Displacement Seal & Unique CMP ‘LRS’™ Outer Load Retention Seal
Sealing Area(s)Cable Inner Bedding & Outer Cable Sheath
Cable Gland Kits AvailableUp to & including size 25 – 2 glands, 2 locknuts, 2 earth tags & 2 LSF shrouds
Size 32 & above – 1 gland, 1 locknut, 1 earth tag & 1 LSF shroud
Optional AccessoriesLocknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
Optional Installation ToolsSpanners, Armour Former Tool

Product Table

Metric

Cable Gland SizeAvailable Entry Threads “C” (Alternate Metric Thread Lengths Available)Cable
Bedding
Diameter
“A”
Overall
Cable
Diameter
“B”
Armour RangeAcross
Flats
“D”
Across
Corners
“D”
Protrusion
Length “F”
(Without Shroud)
Combined Ordering Reference
(*Brass Metric)
Cable
Gland Only
Weight
(Kgs)
StandardOption
MetricThread Length (Metric) “E”NPTThread Length
(NPT) “E”
NPTMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20s16M2010.01/2″19.93/4″3.18.66.113.10.81.2524.026.472.520S16E1WLSF2RA0.16
20SM2010.01/2″19.93/4″6.111.69.515.90.81.2524.026.470.020SE1WLSF2RA0.15
20M2010.01/2″19.93/4″6.513.912.520.90.81.2530.533.673.020E1WLSF2RA0.21
25SM2510.03/4″20.21″11.119.914.022.01.251.637.541.389.025SE1WLSF2RA0.33
25M2510.03/4″20.21″11.119.918.226.21.251.637.541.389.025E1WLSF2RA0.33
32M3210.01″25.01 1/4″17.026.223.733.91.62.046.050.686.032E1WLSF2RA0.43
40M4015.01 1/4″25.61 1/2″22.032.127.940.41.62.055.060.590.040E1WLSF2RA0.62
50SM5015.01 1/2″26.12″29.538.135.246.72.02.560.066.091.050SE1WLSF2RA0.75
50M5015.02″26.92 1/2″35.644.040.453.02.02.570.177.195.050E1WLSF2RA0.95
63SM6315.02″26.92 1/2″40.149.945.659.42.02.575.082.5102.063SE1WLSF2RA1.34
63M6315.02 1/2″39.93″47.255.954.665.82.02.580.088.0104.063E1WLSF2RA1.34
75SM7515.02 1/2″39.93″52.861.959.072.02.02.590.099.0115.075SE1WLSF2RA2.11
75M7515.03″41.53 1/2″59.167.966.778.42.53.0100.0110.0117.075E1WLSF2RA2.42
90M9024.03 1/2″42.84″66.678.676.290.33.154.0114.3125.4147.090E1WLSF2RA4.21
100M10024.04″44.05″76.090.986.1101.43.154.0123.0135.3140.0100E1WLSF2RA4.45
115M11524.04″44.05″86.097.9101.5110.23.154.0133.4146.7162.0115E1WLSF2RA6.19
130M13024.05″46.86″97.0114.9110.2123.23.154.0152.4167.6174.0130E1WLSF2RA8.34
Dimensions displayed in millimeters unless otherwise stated

Imperial

Cable Gland SizeAvailable Entry Threads “C” (Alternate Metric Thread Lengths Available)Cable
Bedding
Diameter
“A”
Overall
Cable
Diameter
“B”
Armour RangeAcross
Flats
“D”
Across
Corners
“D”
Protrusion
Length “F”
(Without Shroud)
Combined Ordering Reference
(*Brass Metric)
Cable
Gland Only
Weight
(Ozs)
StandardOption
MetricThread Length (Metric) “E”NPTThread Length
(NPT) “E”
NPTMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20s16M200.391/2″0.783/4″0.120.340.240.520.030.050.941.042.8520S16E1WLSF2RA5.75
20SM200.391/2″0.783/4″0.240.460.370.630.030.050.941.042.7620SE1WLSF2RA5.29
20M200.391/2″0.783/4″0.260.550.490.820.030.051.201.322.8720E1WLSF2RA7.41
25SM250.393/4″0.801″0.440.780.550.870.050.061.481.633.5025SE1WLSF2RA11.64
25M250.393/4″0.801″0.440.780.721.030.050.061.481.633.5025E1WLSF2RA11.64
32M320.391″0.981 1/4″0.671.030.931.330.060.081.811.993.3932E1WLSF2RA15.17
40M400.591 1/4″1.011 1/2″0.871.261.101.590.060.082.172.383.5440E1WLSF2RA21.87
50SM500.591 1/2″1.032″1.161.501.391.840.080.102.362.603.5850SE1WLSF2RA26.46
50M500.592″1.062 1/2″1.401.731.592.090.080.102.763.043.7450E1WLSF2RA33.51
63SM630.592″1.062 1/2″1.581.961.802.340.080.102.953.254.0263SE1WLSF2RA47.27
63M630.592 1/2″1.573″1.862.22.152.590.080.103.153.464.0963E1WLSF2RA47.27
75SM750.592 1/2″1.573″2.082.442.322.830.080.103.543.904.5375SE1WLSF2RA74.43
75M750.593″1.633 1/2″2.332.672.633.090.100.123.944.334.6175E1WLSF2RA85.36
90M900.943 1/2″1.694″2.623.093.003.560.120.164.504.945.7990E1WLSF2RA148.5
100M1000.944″1.735″2.993.583.393.990.120.164.845.335.51100E1WLSF2RA156.97
115M1150.944″1.735″3.393.854.004.340.120.165.255.786.38115E1WLSF2RA218.35
130M1300.945″1.846″3.824.524.344.850.120.166.006.606.85130E1WLSF2RA294.19
Dimensions displayed in inches unless otherwise stated