    RFOU P1/P8 Power and Control 0.6/1KV Flame Retardant
    NEK 606
    Download Spec Sheet
    RFOU power cable, MUD resistant to NEK606

    Halogen Free 

    Attributes: Armoured Sheathed Flame Retardant Low Smoke 

    Control Panel Heat Dissipation Calculator
    Cable Sizing / Maximum Distance Calculator
    provided by Punch List Zero

    Description

    Conductors: Tinned annealed stranded copper

    Core identification: Single core: off-white 2 core: off-white & black, 3 core: off-white, black & red, 4 core: off-white, black, red & blue.

    Including green / yellow core options. 

    Insulation: Halogen free EPR (Ethylene Propylene Rubber),

    Screen: TCWB (Tinned copper wire braid)

    Sheath/Jacket: Type: SHF, thermoset dual compound, halogen free and mud resistant

    Sheath colours: Black 

    Voltage: 600/1000v

    Operating temperature: Maximum 90°C, minimium bending -40°C

    Cold Bend/Impact: CSA 22.2 NO. 0.3 (-40°C)

    Standards:

    • IEC60092-353: electrical installation in ships, power cables
    • NEK606: cables for offshore installation halogen-free or mud-resistant
    • IEC60092.375: shipboard telecommunications cable
    • IEC60331: fire resistant
    • IEC60332: flame retardant
    • IEC61031-1.2: smoke denisty
    • IEC60754-1: halogen free properties
    • IEC60228: electical conductor

    Applications: Mud resistant cables suitable for control, lighting and power systems

    Type Approvals: ABS, DNV Lloyd’s Register of Shipping

    Product Table

    Classification Information

    Classification Code Construction Detail
    Conductor Stranded tinned annealed copper wires as per IEC 60228, Class 2
    Insulation R Halogen free EPR compound as per IEC 60092-351
    Cabling - Insulated cores shall be cabled.
    - Flame retardant and non-hygroscopic fillers may be used.
    - Suitable tape(s) may be applied on the cabled core.
    Inner covering F Flame retardant halogen free thermoset compound
    Armor O (B) - Braid of tinned annealed copper wire(O) / bronze wire(B)
    -Coverage density : Min. 90%
    - A suitable separator tape(s) may be applied under/over the armor
    Sheath U - SHF2 or SHF Mud as per IEC 60092-359
    - Outer sheath color : Black

    Core Identification

    No. of Cores Without Earth Core With Earth Core
    1C Off-white
    2C Black, White
    3C / 2C+E Black, White, Red Black, White, G/Y
    4C / 3C+E Black, White, Red, Blue Black, White, Red, G/Y
    5C / 4C+E Black No. on white insulation Black, White, Red, Blue, G/Y
    6C and above Black No. on white insulation Black No. on white insulation, G/Y