Products > 797
797 series male to male / female to female

797
797 series male to male / female to female

Available brass, nickel plated brass, aluminium & stainless steel

Description

Technical

Male-Male or Female-Female Adaptor, Globally Approved, Explosive Atmosphere Cable / Conduit Accessory

• Designed to convert existing threads
• General purpose / industrial version available
• Supplied with male or female threads
• Can be supplied with thread conversion
• Equipment interface ‘O’ ring seal available on male-male
• -60°C to +200°C
• Globally marked, IECEx, ATEX & cCSAus
• Can be used with 737 (not Ex d direct entry applications)

Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444
Enclosure Protection IK10 to IEC 62262 (20 joules) Brass & Stainless Steel Only
ATEX Certificate SIRA13ATEX1265X
Code of Protection II 2 G Ex d IIC Gb,Ex e IIC Gb, II 1 D Ex ta IIIC Da
IM2 Ex d I Mb, Ex e I Mb
Compliance Standards EN 60079-0,1,7,31
IECEx Certificate IECEx SIR13.0094X
Code of Protection Ex d I Mb/ Ex e I Mb/ Ex d IIC Gb / Ex e IIC Gb / Ex ta IIIC Da
Compliance Standards IEC 60079-0,1,7,31
cCSAus Certificate 1055233
Code of Protection Ex de II; Class I, Groups A, B, C and D; Class I, Zone 1, AEx de II; IP66, 67, and 68, Enclosure Type 4X.
Compliance Standards C22.2 No. 0, 0.5-M1982, 30, 94, CAN/CSA E60079-0,1,7, UL 50, Edition 11, UL 1203, Edition 4,
UL 60079-0,1,7
EAC Certificate (Formerly GOST R, K & B) TC RU C-GB.AA87.B.00487
GOST R Certificate POCC.GB.35.H00102
KCC Certificate 14-GA4BO-0250X
CCOE / PESO (India) Certificate P333688
NEPSI Certificate GYJ13.1142X
INMETRO Approval TÜV 12.1332X
RETIE Approval 03866
Marine Approvals LRS: 01/00173, ABS: 17-LD1619350-PDA
Ingress Protection Rating ** IP66, IP67 & IP68 (when fitted with CMP sealing accessories)
Available Materials Brass, Electroless Nickel Plated Brass, Aluminium, Stainless Steel

Product Table

Metric

Type Ordering Reference Male/Female Forward Thread Size “C” Minimum
Thread Length “E”
Male/Female Rear Thread “A” Across Flats “D” Across Corners “D” Bore Diameter “B” Protrusion “F “ Installation
Torque (Nm)
Female 797DM1FM1F M16 X 1.5 15.0 M16 X 1.5 24.0 26.4 14.0 34.0 7.0
797DM2FM2F M20 X 1.5 15.0 M20 X 15 24.0 26.4 14.0 36.0 7.0
797DM3FM3F M25 X 1.5 15.0 M25 X 1.5 30.5 33.5 16.0 36.6 10.0
797DM4FM4F M32 X 1.5 15.0 M32 X 1.5 36.0 39.6 27.7 37.0 15.0
797DM5FM5F M40 X 1.5 15.0 M40 X 1.5 46.0 50.6 33.0 37.6 25.0
797DM6FM6F M50 X 1.5 15.0 M50 X 1.5 55.0 60.5 45.5 40.6 30.0
797DM7FM7F M63 X 1.5 15.0 M63 X 1.5 70.1 77.1 57.5 40.6 45.0
797DM8FM8F M75 X 1.5 15.0 M75 X 1.5 80.0 88.0 68.2 37.0 45.0
797DM9FM9F M90 X 2.0 24.0 M90 X 2.0 100.0 110.0 82.0 52.0 45.0
797DM10FM10F M100 X 2.0 24.0 M100 X 2.0 108.0 118.8 91.0 52.0 45.0
Male 797DM1MM1M M16 X 1.5  15.0 M16 X 1.5 24.0 26.4 10.0 18.0 7.0
797DM2MM2M M20 X 1.5 15.0 M20 X 15 24.0 26.4 14.0 18.0 7.0
797DM3MM3M M25 X 1.5 15.0 M25 X 1.5 30.5 33.5 20.0 18.0 10.0
797DM4MM4M M32 X 1.5 15.0 M32 X 1.5 36.0 39.6 26.8 20.0 15.0
797DM5MM5M M40 X 1.5 15.0 M40 X 1.5 46.0 50.6 32.7 20.0 25.0
797DM6MM6M M50 X 1.5 15.0 M50 X 1.5 55.0 60.5 44.1 20.0 30.0
797DM7MM7M M63 X 1.5 15.0 M63 X 1.5 70.1 77.1 55.6 20.0 45.0
797DM8MM8M M75 X 1.5 15.0 M75 X 1.5 80.0 88.0 65.6 21.0 45.0
797DM9MM9M M90 X 2.0 24.0 M90 X 2.0 100.0 110.0 82.0 23.0 45.0
797DM10M10M M100 X 2.0 24.0 M100 X 2.0 108.0 118.8 91.1 23.0 45.0
Dimensions shown in millimeters unless otherwise stated

Imperial

Type Ordering Reference Male/Female Forward Thread Size “C” Minimum
Thread Length “E”
Male/Female Rear Thread “A” Across Flats “D” Across Corners “D” Bore Diameter “B” Protrusion “F ” Installation
Torque (Nm)
Female 797DM1FM1F M16 X 1.5 0.59 M16 X 1.5 0.94 1.04 0.55 1.34 7.0
797DM2FM2F M20 X 1.5 0.59 M20 X 15 0.94 1.04 0.55 1.42 7.0
797DM3FM3F M25 X 1.5 0.59 M25 X 1.5 1.20 1.32 0.63 1.44 10.0
797DM4FM4F M32 X 1.5 0.59 M32 X 1.5 1.42 1.56 1.09 1.46 15.0
797DM5FM5F M40 X 1.5 0.59 M40 X 1.5 1.81 1.99 1.30 1.48 25.0
797DM6FM6F M50 X 1.5 0.59 M50 X 1.5 2.17 2.38 1.79 1.60 30.0
797DM7FM7F M63 X 1.5 0.59 M63 X 1.5 2.76 3.04 2.26 1.60 45.0
797DM8FM8F M75 X 1.5 0.59 M75 X 1.5 3.15 3.46 2.69 1.46 45.0
797DM9FM9F M90 X 2.0 0.94 M90 X 2.0 3.94 4.33 3.23 2.05 45.0
797DM10FM10F M100 X 2.0 0.94 M100 X 2.0 4.25 4.68 3.59 2.05 45.0
Male 797DM1MM1M M16 X 1.5 0.59 M16 X 1.5 0.94 1.04 0.39 0.71 7.0
797DM2MM2M M20 X 1.5 0.59 M20 X 15 0.94 1.04 0.55 0.71 7.0
797DM3MM3M M25 X 1.5 0.59 M25 X 1.5 1.20 1.32 0.79 0.71 10.0
797DM4MM4M M32 X 1.5 0.59 M32 X 1.5 1.42 1.56 1.06 0.79 15.0
797DM5MM5M M40 X 1.5 0.59 M40 X 1.5 1.81 1.99 1.29 0.79 25.0
797DM6MM6M M50 X 1.5 0.59 M50 X 1.5 2.17 2.38 1.74 0.79 30.0
797DM7MM7M M63 X 1.5 0.59 M63 X 1.5 2.76 3.04 2.19 0.79 45.0
797DM8MM8M M75 X 1.5 0.59 M75 X 1.5 3.15 3.46 2.58 0.83 45.0
797DM9MM9M M90 X 2.0 0.94 M90 X 2.0 3.94 4.33 3.23 0.91 45.0
797DM10M10M M100 X 2.0 0.94 M100 X 2.0 4.25 4.68 3.59 0.91 45.0
Dimensions shown in millimeters unless otherwise stated

Download Spec Sheet

Download

Technical

Male-Male or Female-Female Adaptor, Globally Approved, Explosive Atmosphere Cable / Conduit Accessory

• Designed to convert existing threads
• General purpose / industrial version available
• Supplied with male or female threads
• Can be supplied with thread conversion
• Equipment interface ‘O’ ring seal available on male-male
• -60°C to +200°C
• Globally marked, IECEx, ATEX & cCSAus
• Can be used with 737 (not Ex d direct entry applications)

Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444
Enclosure Protection IK10 to IEC 62262 (20 joules) Brass & Stainless Steel Only
ATEX Certificate SIRA13ATEX1265X
Code of Protection II 2 G Ex d IIC Gb,Ex e IIC Gb, II 1 D Ex ta IIIC Da
IM2 Ex d I Mb, Ex e I Mb
Compliance Standards EN 60079-0,1,7,31
IECEx Certificate IECEx SIR13.0094X
Code of Protection Ex d I Mb/ Ex e I Mb/ Ex d IIC Gb / Ex e IIC Gb / Ex ta IIIC Da
Compliance Standards IEC 60079-0,1,7,31
cCSAus Certificate 1055233
Code of Protection Ex de II; Class I, Groups A, B, C and D; Class I, Zone 1, AEx de II; IP66, 67, and 68, Enclosure Type 4X.
Compliance Standards C22.2 No. 0, 0.5-M1982, 30, 94, CAN/CSA E60079-0,1,7, UL 50, Edition 11, UL 1203, Edition 4,
UL 60079-0,1,7
EAC Certificate (Formerly GOST R, K & B) TC RU C-GB.AA87.B.00487
GOST R Certificate POCC.GB.35.H00102
KCC Certificate 14-GA4BO-0250X
CCOE / PESO (India) Certificate P333688
NEPSI Certificate GYJ13.1142X
INMETRO Approval TÜV 12.1332X
RETIE Approval 03866
Marine Approvals LRS: 01/00173, ABS: 17-LD1619350-PDA
Ingress Protection Rating ** IP66, IP67 & IP68 (when fitted with CMP sealing accessories)
Available Materials Brass, Electroless Nickel Plated Brass, Aluminium, Stainless Steel

Product Table

Metric

Type Ordering Reference Male/Female Forward Thread Size “C” Minimum
Thread Length “E”
Male/Female Rear Thread “A” Across Flats “D” Across Corners “D” Bore Diameter “B” Protrusion “F “ Installation
Torque (Nm)
Female 797DM1FM1F M16 X 1.5 15.0 M16 X 1.5 24.0 26.4 14.0 34.0 7.0
797DM2FM2F M20 X 1.5 15.0 M20 X 15 24.0 26.4 14.0 36.0 7.0
797DM3FM3F M25 X 1.5 15.0 M25 X 1.5 30.5 33.5 16.0 36.6 10.0
797DM4FM4F M32 X 1.5 15.0 M32 X 1.5 36.0 39.6 27.7 37.0 15.0
797DM5FM5F M40 X 1.5 15.0 M40 X 1.5 46.0 50.6 33.0 37.6 25.0
797DM6FM6F M50 X 1.5 15.0 M50 X 1.5 55.0 60.5 45.5 40.6 30.0
797DM7FM7F M63 X 1.5 15.0 M63 X 1.5 70.1 77.1 57.5 40.6 45.0
797DM8FM8F M75 X 1.5 15.0 M75 X 1.5 80.0 88.0 68.2 37.0 45.0
797DM9FM9F M90 X 2.0 24.0 M90 X 2.0 100.0 110.0 82.0 52.0 45.0
797DM10FM10F M100 X 2.0 24.0 M100 X 2.0 108.0 118.8 91.0 52.0 45.0
Male 797DM1MM1M M16 X 1.5  15.0 M16 X 1.5 24.0 26.4 10.0 18.0 7.0
797DM2MM2M M20 X 1.5 15.0 M20 X 15 24.0 26.4 14.0 18.0 7.0
797DM3MM3M M25 X 1.5 15.0 M25 X 1.5 30.5 33.5 20.0 18.0 10.0
797DM4MM4M M32 X 1.5 15.0 M32 X 1.5 36.0 39.6 26.8 20.0 15.0
797DM5MM5M M40 X 1.5 15.0 M40 X 1.5 46.0 50.6 32.7 20.0 25.0
797DM6MM6M M50 X 1.5 15.0 M50 X 1.5 55.0 60.5 44.1 20.0 30.0
797DM7MM7M M63 X 1.5 15.0 M63 X 1.5 70.1 77.1 55.6 20.0 45.0
797DM8MM8M M75 X 1.5 15.0 M75 X 1.5 80.0 88.0 65.6 21.0 45.0
797DM9MM9M M90 X 2.0 24.0 M90 X 2.0 100.0 110.0 82.0 23.0 45.0
797DM10M10M M100 X 2.0 24.0 M100 X 2.0 108.0 118.8 91.1 23.0 45.0
Dimensions shown in millimeters unless otherwise stated

Imperial

Type Ordering Reference Male/Female Forward Thread Size “C” Minimum
Thread Length “E”
Male/Female Rear Thread “A” Across Flats “D” Across Corners “D” Bore Diameter “B” Protrusion “F ” Installation
Torque (Nm)
Female 797DM1FM1F M16 X 1.5 0.59 M16 X 1.5 0.94 1.04 0.55 1.34 7.0
797DM2FM2F M20 X 1.5 0.59 M20 X 15 0.94 1.04 0.55 1.42 7.0
797DM3FM3F M25 X 1.5 0.59 M25 X 1.5 1.20 1.32 0.63 1.44 10.0
797DM4FM4F M32 X 1.5 0.59 M32 X 1.5 1.42 1.56 1.09 1.46 15.0
797DM5FM5F M40 X 1.5 0.59 M40 X 1.5 1.81 1.99 1.30 1.48 25.0
797DM6FM6F M50 X 1.5 0.59 M50 X 1.5 2.17 2.38 1.79 1.60 30.0
797DM7FM7F M63 X 1.5 0.59 M63 X 1.5 2.76 3.04 2.26 1.60 45.0
797DM8FM8F M75 X 1.5 0.59 M75 X 1.5 3.15 3.46 2.69 1.46 45.0
797DM9FM9F M90 X 2.0 0.94 M90 X 2.0 3.94 4.33 3.23 2.05 45.0
797DM10FM10F M100 X 2.0 0.94 M100 X 2.0 4.25 4.68 3.59 2.05 45.0
Male 797DM1MM1M M16 X 1.5 0.59 M16 X 1.5 0.94 1.04 0.39 0.71 7.0
797DM2MM2M M20 X 1.5 0.59 M20 X 15 0.94 1.04 0.55 0.71 7.0
797DM3MM3M M25 X 1.5 0.59 M25 X 1.5 1.20 1.32 0.79 0.71 10.0
797DM4MM4M M32 X 1.5 0.59 M32 X 1.5 1.42 1.56 1.06 0.79 15.0
797DM5MM5M M40 X 1.5 0.59 M40 X 1.5 1.81 1.99 1.29 0.79 25.0
797DM6MM6M M50 X 1.5 0.59 M50 X 1.5 2.17 2.38 1.74 0.79 30.0
797DM7MM7M M63 X 1.5 0.59 M63 X 1.5 2.76 3.04 2.19 0.79 45.0
797DM8MM8M M75 X 1.5 0.59 M75 X 1.5 3.15 3.46 2.58 0.83 45.0
797DM9MM9M M90 X 2.0 0.94 M90 X 2.0 3.94 4.33 3.23 0.91 45.0
797DM10M10M M100 X 2.0 0.94 M100 X 2.0 4.25 4.68 3.59 0.91 45.0
Dimensions shown in millimeters unless otherwise stated