Cable Designation 2kV TPN(VFD), TPNB(VFD), TPNBS(VFD) Application Standard - Design guide : IEEE 1580(2010) UL 1309(2017) - Insulation material : IEEE 1580, Type P UL 1309, X 110 - Sheath material : IEEE 1580, Type N - Flame retardant : IIEEE 1202 & IEC 60332-3 Category A - Cold bend / impact : CSA C22.2 NO. 2556(-40℃/-40℃) (Fomerly CSA C22.2…
Cable Designation FIRE RESISTANCE 0.6/1kV FS-TP(IS-OS)PN, FS-TP(IS-OS)PNB, FS-TP(IS-OS)PNBS Application Standard - Design guide : IEEE 1580(2010) UL 1309(2017) - Insulation material : IEEE 1580, Type P UL 1309, X110 - Sheath material : IEEE 1580, Type N - Flame retardant : IEEE 1202 & IEC 60332-3 Category A - Fire resistance : IEC 60331-21(90min), IEC 60331-1,-2(120min), FS- type only -…
Cable Designation FLAME RETARDANT 0.6/1kV TP(IS-OS)PN, TP(IS-OS)PNB, TP(IS-OS)PNBS Application Standard - Design guide : IEEE 1580(2010) UL 1309(2017) - Insulation material : IEEE 1580, Type P UL 1309, X110 - Sheath material : IEEE 1580, Type N - Flame retardant : IEEE 1202 & IEC 60332-3 Category A - Fire resistance : IEC 60331-21(90min), IEC 60331-1,-2(120min), FS- type only -…
Cable Designation FIRE RESISTANCE 0.6/1kV FS-TP(IS)PN, FS-TP(IS)PNB, FS-TP(IS)PNBS Application Standard - Design guide : IEEE 1580(2010) UL 1309(2017) - Insulation material : IEEE 1580, Type P UL 1309, X110 - Sheath material : IEEE 1580, Type N - Flame retardant : IEEE 1202 & IEC 60332-3 Category A - Fire resistance : IEC 60331-21(90min) IEC 60331-1,-2(120min) FS- type only -…
Cable Designation FLAME RETARDANT 0.6/1kV TP(OBS)PN, TP(OBS)PNB, TP(OBS)PNBS Application Standard - Design guide : IEEE 1580(2010) UL 1309(2017) - Insulation material : IEEE 1580, Type P UL 1309, X110 - Sheath material : IEEE 1580, Type N - Flame retardant : IEEE 1202 & IEC 60332-3 Category A - Fire resistance : IEC 60331-21(90min) IEC 60331-1,-2(120min) FS- type only -…
Cable Designation FIRE RESISTANCE 0.6/1kV FS-TP(OBS)PN, FS-TP(OBS)PNB, FS-TP(OBS)PNBS Application Standard - Design guide : IEEE 1580(2010) UL 1309(2017) - Insulation material : IEEE 1580, Type P UL 1309, X110 - Sheath material : IEEE 1580, Type N - Flame retardant : IEEE 1202 & IEC 60332-3 Category A - Fire resistance : IEC 60331-21(90min) IEC 60331-1,-2(120min) FS- type only -…
Cable Designation FLAME RETARDANT 0.6/1kV TP(OBS)PN, TP(OBS)PNB, TP(OBS)PNBS Application Standard - Design guide : IEEE 1580(2010) UL 1309(2017) - Insulation material : IEEE 1580, Type P UL 1309, X110 - Sheath material : IEEE 1580, Type N - Flame retardant : IEEE 1202 & IEC 60332-3 Category A - Fire resistance : IEC 60331-21(90min) IEC 60331-1,-2(120min) FS- type only -…
Cable Designation FIRE RESISTANCE 0.6/1kV FS-TT(OS)PN, FS-TT(OS)PNB, FS-TT(OS)PNBS Application Standard - Design guide : IEEE 1580(2010) UL 1309(2017) - Insulation material : IEEE 1580, Type P UL 1309, X110 - Sheath material : IEEE 1580, Type N - Flame retardant : IEEE 1202 & IEC 60332-3 Category A - Fire resistance : IEC 60331-21(90min), IEC 60331-1,-2(120min), FS- type only -…
Cable Designation FLAME RETARDANT 0.6/1kV TT(OS)PN, TT(OS)PNB, TT(OS)PNBS Application Standard - Design guide : IEEE 1580(2010) UL 1309(2017) - Insulation material : IEEE 1580, Type P UL 1309, X110 - Sheath material : IEEE 1580, Type N - Flame retardant : IEEE 1202 & IEC 60332-3 Category A - Fire resistance : IEC 60331-21(90min), IEC 60331-1,-2(120min), FS- type only -…
Cable Designation FIRE RESISTANCE 0.6/1kV FS-TP(IS-OS)PN, FS-TP(IS-OS)PNB, FS-TP(IS-OS)PNBS Application Standard - Design guide : IEEE 1580(2010) UL 1309(2017) - Insulation material : IEEE 1580, Type P UL 1309, X110 - Sheath material : IEEE 1580, Type N - Flame retardant : IEEE 1202 & IEC 60332-3 Category A - Fire resistance : IEC 60331-21(90min), IEC 60331-1,-2(120min), FS- type only -…
Cable Designation FLAME RETARDANT 0.6/1kV TP(IS-OS)PN, TP(IS-OS)PNB, TP(IS-OS)PNBS Application Standard - Design guide: IEEE 1580(2010) UL 1309(2017) - Insulation material: IEEE 1580, Type P UL 1309, X110 - Sheath material: IEEE 1580, Type N - Flame retardant: IEEE 1202 & IEC 60332-3 Category A - Fire resistance : IEC 60331-21(90min), IEC 60331-1,-2(120min), FS- type only - Cold bend / impact…